hitachi — MC: MAIN CONTROLLER

SYSTEM / Controller Monitor Unit Secondary Crusher Cylinder MC Selector Valve Attachment Selection Signal Auxiliary Flow Rate Control From Pump 1 Auxiliary Flow Combiner Valve Control Valve Solenoid Valve Fine Adjustment Signal Attachment Selection Signal ICF Dr.ZX CAN Bus Line Auxiliary Flow Rate Control Solenoid Valve Pressure Sensor Travel From Pilot Pump Swing Boom Raise Auxiliary Flow Rate Control Valve Arm Roll-Out Auxiliary From Attachment Pilot Valve From Pump 2 Auxiliary Flow Combining Solenoid Valve Bypass Shut-Out Valve T1V5-02-01-004 NOTE: The illustration shows the circuit of secondary crusher 1. T2-1-17