X WEIGHT (ADDITIONAL COUNTERWEIGHT) REMOVAL AND INSTALLATION METHOD ATTACHMENTS X WEIGHT (ADDITIONAL COUNTERWEIGHT) REMOVAL AND INSTALLATION METHOD 0. Weight Installation and Removal Method 0. For lifting this machine, use a wire rope with sufficient strength to withstand the machine weight. Do not attempt to lift the machine in a posture other than that explained below. Otherwise there is the danger that the lifted machine may become unbalanced in the air. Lift the machine keeping it level. 1. Remove the nameplate at the rear of the machine. 2. Lift up the X weight (additional counterweight) with a crane and install it behind the standard counterweight.
REMARK The appropriate length of the wire rope is indicated below. (A) Wire rope: Total length 800 mm (31.5 in) Rope diameter: 9 mm (0.4 in) (B) Eyebolt X Weight (additional counterweight) weight: 170 kg (375 lb) 6-20 WARNING