OPERATION LONG TERM STORAGE LONG TERM STORAGE BEFORE STORAGE NOTICE When storing the machine, set the machine in the posture shown in the diagram on the right to protect the cylinder rod. (To prevent rusting of the cylinder rod) When putting the machine in storage for a long time, do as fol- lows. G Clean and wash all parts, then store the machine indoors. If the machine has to be stored outdoors, select level ground and cover the machine with a sheet. G Completely fill the fuel tank, lubricate and change the oil before storage. G Apply a thin coat of grease to the metal surface of the hydraulic piston rods.
G Disconnect the negative terminals of the battery and cover it or remove it from the machine and store it sepa- rately. G Komatsu genuine Super Coolant (AF-ACL) is added to the cooling water, so there is no need to change the density for temperatures above -10°C (14єF). If the temperature goes below -10°C (14єF), adjust the density. For details, see "CLEAN INSIDE OF COOL- ING SYSTEM (PAGE 4-23)". G Lock each control lever and pedal with the lock lever and pedal lock. G Set the stop valve to the LOCK position on machines which can install attachments. Install a plug in the elbow.
DURING STORAGE If it is unavoidably necessary to carry out the rust-preventive operation while the machine is indoors, open the doors and windows to improve ventilation and prevent gas poisoning. During storage, always operate the machine once a month so that a new film of oil will be coated over movable parts and component surfaces. At the same time, also charge the battery. G For machines equipped with an air conditioner, run the air conditioner. G Rotate the tracks. 3-75 WARNING