Komatsu — CLEAN INSIDE OF COOLING SYSTEM

MAINTENANCE PROCEDURE MAINTENANCE Mixing rate of water and antifreeze Antifreeze is flammable, so keep it away from flame. Antifreeze is toxic. When removing the drain plug, be careful not to get water containing antifreeze on you. I If it gets in your eyes, flush your eyes with large quantities of fresh water and see a doctor at once. Use city water for the cooling water. If river water, well water or other such water supply must be used, contact your Komatsu distributor. We recommend use of an antifreeze density gauge to control the mixing proportions. G Prepare a container to catch drained coolant: Min 5.6 liters (1.48 US gal) capacity. G Prepare a water inlet hose. 1.

Remove 2 bolts (1) from the cover on the right side of the machine, then remove the cover above the radiator cap. 2. Check that the cooling water temperature has gone down enough to make it possible to touch the radiator cap sur- face by hand, then turn radiator cap (2) slowly until it con- tacts the stopper to release the pressure. 3. Following this, push radiator cap (2), turn it until it con- tacts the stopper, then remove it. 4-24 Min. atmospheric temperature °C -10 -15 -20 -25 °F 14 5 -4 -13 Amount of antifreeze liters 1.1 1.2 1.4 1.6 US gal 0.29 0.32 0.37 0.59 Amount of water liters 2.3 2.2 2.0 1.8 US gal 0.61 0.81 0.53 0.48 WARNING