. OPERATION DETAILED CONTROLS AND GAUGES Other Functions 3 - 54 Self-diagnostic Function It is possible to perform t roubleshooting of various sensors and equipment used on the a ir conditioner. 1. Pres s OFF switch (1 ). The temperature settin g and air flow display on the liquid crys tal display portion go out and o peration stops. 2. If the "∨ " and " ∧ " part s of temperatur e setting s witch (3) are k ept pressed at the same ti me for at least 3 seconds, the tr oubleshooting mode is displayed on the l iquid crystal display portion.
display and failure Display Failure mode E-- No failure E11 Disconnection in recirculated air sensor E12 Short circuit in recirculated air sensor E13 Disconnection in fresh air sensor E14 Short circuit in fresh air sensor E15 Disconnection in coolant temperature sensor E16 Short circuit in coolant temperature sensor E18 Short circuit in sunlight sensor E21 Disconnection in vent sensor E22 Short circuit in vent sensor E43 Problem in vent damper E44 Problem in air mix damper E45 Problem in RECIRC/FRESH air damper E51 Problem in refrigerant pressure