. OPERATION MACHINE OPERATIONS AND CONTROLS STARTING ENGINE Normal Starting WARNING particularly careful to ensure good ventilation. 1. Check the safety lock lever (1) is at the LOCK position. If the safety lock lever is in the FREE position, the engine does not start. 2. Set fuel control dial (2) at the low idle (MIN) position. If it is at the high idle (MAX) position, always change it to the low idle (MIN) position. 3 - 87 Do not attempt to start the eng circuit. Such an act may caus ine by short-circuiting the engine starting e a serious bodily injury or fire. Check that there are no pers then sound the horn and star Exhaust gas is toxic.
When s ons or obstacles in the surrounding area, t the engine. tarting the engine in confined spaces, be NOTICE Before starting the engine, ch eck that the fuel control dial is at the low idle (MIN) position. If the fuel control dial is at the suddenly and cause damage FULL position, the engine will accelerate to the engine parts. Do not crank the starting mot or continuously for more than 20 seconds. If the engine does not start, again. wait for at least 2 minutes before trying REMARK If the engine is stopped when it is not fully warmed up and it is started again a few minutes lat er, there may be a delay in the engine rotation during cranking.
This is caused by fuel gas remaining inside the cylin der; it does not indicate any abnormality. In addition, even if this phenomenon occurs, there is no problem with the reliability or durability of the engine or other parts.