. OPERATION TROUBLES AND ACTIONS Machine Monitoring System (*): For details of the method of handling the emergency pump drive switch and swing holding brake cancel switch, see "SWITCHES (PAGE 3-29)". 3 - 146 Electronic Control System If an error code appears on the machine monitor display (normally displays TIME), follow the countermeasure table as shown below in the self-diagnosis. Monitor display Error mode Remedy E02 Error in pump control system When emergency pump drive switch is up, normal operations become normal, but carry out inspection immediately. (*) E03 Error in swing brake system Turn the swing holding brake release switch is up to release the brake.
When applying the swing brake, operate it manually with the swing lock switch. Depending on the cause of the problem, it may not be possible to release it. In any case, have it inspected immediately. (*) E10 Error in fuel line and swing sensor system (engine stop) Have inspection carried out immediately. E11 Error in engine controller system (engine protection, output down) Move machine to a safe posture, and carry out inspection immediately. E14 Error in throttle system Move machine to a safe posture, and carry out inspection immediately. E15 Error in sensor and engine controller power source It is possible to carry out normal driving operations, but have inspection carried out immediately.
E0E Network error Move machine to a safe posture, and carry out inspection immediately. In the case where the monitor will not display error codes and work equipment operation and swing operation cannot be carried out. Have inspection carried out immediately.