Komatsu — EVERY 500 HOURS MAINTENANCE

. MAINTENANCE MAINTENANCE PROCEDURE NOTICE REMARK 4 - 55 . When installing, tighte n until th e packing s urface c ontacts the seal surface of t he filter ho lder, then tighten it up 1/2 to 3/4 of a turn. If the filter cartridge is tightene d too far, th e packin g will b e damaged and t his will lead to leakage of fuel. If the filter c artridge is too lo ose, fue l will also le ak from the packing , so always tighten to the . With this machine, it is unnecessary to bleed th e air. After carryi ng o ut the operations in Steps 1 - 5, turn the starting switc h to t he START position and s tart th e engine Do not cra nk th e starting mot or continuousl y for m ore than 2 0 secon ds.

If th e engine does not start, wai t for at lea st two minut es before trying to start again. If the fuel piping has been remove d, bleed th e air also from t he injection pump air bleed val