Connecting Rod - Bend and Twist Inspection (1-15) Section 1 - Cylinder Block - Group 01 M11 Page 1-46 Connecting Rod - Limits of Acceptance An indication is open if it can be seen with the naked eye in a well lighted area. Many times an open indication can be felt with a fingernail. The connecting rod must be replaced if any indications are visible in the critical areas shown. NOTE: The connecting rod must have all magnetism re- moved completely and cleaned thoroughly. Remove all magnetism from the connecting rod. Warning: When using a steam cleaner, wear protective clothing and safety glasses or a face shield. Hot steam will cause serious personal injury.
Use solvent or steam clean the connecting rod and dry with compressed air. Connecting Rod - Bend and Twist Inspection (1-15) Fixture Calibration Use checking fixture, Part No. ST-561, and mandrel set, Part No. 3376690, to inspect the bend and twist of the conecting rod. Calibrate the checking fixture with a new rod that has been measured for correct center to center length, 217.975 to 218.025 mm [8.5817 to 8.5836 inch]. Assemble the connecting rod cap to the rod. Refer to Procedure 1-13.