TROUBLESHOOTING / Troubleshooting A Pump Failure T5-6-6 Fault Code Trouble Cause Influenced Control 11200-3 Abnormal Pump 1 Delivery Pressure Sensor High Volt- age Voltage: 4.5 V or higher • HP Mode Control • Travel HP Mode Control • E Mode Control • Travel Torque-Up Control • Arm Regenerative Control • Digging Regenerative Control • Auto-Power Lift Control • Travel Motor Swash Angle Control 11200-4 Abnormal Pump 1 Delivery Pressure Sensor Low Voltage Voltage:
Less than 0.25 V • HP Mode Control • Travel HP Mode Control • E Mode Control • Travel Torque-Up Control • Arm Regenerative Control • Digging Regenerative Control • Auto-Power Lift Control • Travel Motor Swash Angle Control 11202-3 Abnormal Pump 2 Delivery Pressure Sensor High Volt- age Voltage: 4.5 V or higher • HP Mode Control • Travel HP Mode Control • E Mode Control • Travel Torque-Up Control • Arm Regenerative Control • Digging Regenerative Control • Travel Motor Swash Angle Control 11202-4 Abnormal Pump 2 Delivery Pressure Sensor Low Voltage Voltage:
Less than 0.25 V • HP Mode Control • Travel HP Mode Control • E Mode Control • Travel Torque-Up Control • Arm Regenerative Control • Digging Regenerative Control • Travel Motor Swash Angle Control 11206-3 Abnormal Pump 1 Pump Control Pressure Sensor High Voltage Voltage: 4.75 V or higher • E Mode Control • Heater Control • Travel Motor Swash Angle Control 11206-4 Abnormal Pump 1 Pump Control Pressure Sensor Low Voltage Voltage: Less than 0.25 V • E Mode Control • Heater Control • Travel Motor Swash Angle Control 11208-3 Abnormal Pump 2 Pump Control Pressure Sensor High Voltage Voltage:
4.75 V or higher • E Mode Control • Heater Control • Travel Motor Swash Angle Control 11208-4 Abnormal Pump 2 Pump Control Pressure Sensor Low Voltage Voltage: Less than 0.25 V • E Mode Control • Heater Control • Travel Motor Swash Angle Control