TROUBLESHOOTING / Troubleshooting A T5-6-9 Symptoms in Machine Opera- tion When Trouble Occurs. Remedy for Dr. ZX Remark • Combined operation of arm-roll-in and swing: Arm speed is slow. • In case of the machine equipped with the swing alarm (optional) and when swing alarm is effective, swing alarm continues to ring. Retrial B • Check Harness • Replace Swing Pilot Pressure Sensor • Combined operation of arm-roll-in and swing: Arm speed is slow. • In case of the machine equipped with the swing alarm (optional) and when swing alarm is effective, swing alarm continues to ring.
Retrial B • Check Harness • Replace Swing Pilot Pressure Sensor • During HP control, boom raise speed does not in- crease. • Combined operation of arm roll-in and boom raise: Arm speed is slow. Retrial B • Check Harness • Replace Boom Raise Pilot Pressure Sensor • During HP control, boom raise speed does not in- crease. • Combined operation of arm roll-in and boom raise: Arm speed is slow. Retrial B • Check Harness • Replace Boom Raise Pilot Pressure Sensor • During HP control, arm roll-in speed does not increase. • Combined operation of arm roll-in and swing: Arm speed is slow.
Retrial B • Check Harness • Replace Arm Roll-In Pilot Pressure Sensor • During HP control, arm roll-in speed does not increase. • Combined operation of arm roll-in and swing: Arm speed is slow. Retrial B • Check Harness • Replace Arm Roll-In Pilot Pressure Sensor