hitachi — MC FAULT CODE 11208

TROUBLESHOOTING / Troubleshooting A MC FAULT CODE 11208 YES Faulty MC. Check if voltage between terminal #C1 of harness end of connector MC-C and machine is 0 V. A Shorted circuit in harness between MC and pump 2 control pressure sensor. Connector (Harness end of connector viewed from the open side) · Key switch: ON NO MC Connector MC-D Pump Control Pressure Sensor #D14 T183-05-04-009 T5-6-78 Fault Code Trouble Cause Influenced Control 11208-3 Abnormal Pump 2 Control Pressure Sensor High Voltage Voltage: 4.75 V or higher • E Mode Control • Heater Control • Travel Motor Swash Angle Selection Control 11208-4 Abnormal Pump 2 Control Pressure Sensor Low Voltage Voltage:

Less than 0.25 V • E Mode Control • Heater Control • Travel Motor Swash Angle Selection Control Disconnect connector MC-D of MC. Open circuit in harness Check for continuity in YES between MC and pump 2 harnes between control pressure sensor. terminal #D14 of YES harness end of connector MC-D in MC Disconnect connector and terminal #2 in of pump 2 control pump 2 control To A pressure sensor. pressure sensor. NO Check if voltage NO between terminals #1 and #3 of harness end of connector is 5±0.5 Check if voltage YES Open circuit in harness between terminal #1 of between MC and pump 2 V. harness end of control pressure sensor Switch pump 1 control · Key switch:

ON connector in pump 2 (terminal #3). pressure sensor with NO control pressure pump 2 control pressure sensor and machine is Open circuit in harness sensor and retry. specification. between MC and pump 2 Check if fault code is NO control pressure sensor switched. · Key switch: ON (terminal #1). · Specification: More than 0.25 V, Less than 4.75 V Faulty pump 2 control YES pressure sensor. Faulty pump 2 control pressure sensor. YES 1 2 3