hitachi — ENGINE SYSTEM TROUBLESHOOTING

TROUBLESHOOTING / Troubleshooting B E-5 Engine speed does not increase when en- gine starts. Related MC Fault Code: 11004-2, 11901-3, 11901-4 Refer to the pages for the Auto Warming Up Con- trol in the SYSTEM / Control System group in the T/M (Operational Principle). Check the wiring connections first. 0 ° C or higher when starting Normal. NO Monitor oil temperature. Faulty key switch, or open circuit in harness between key switch and MC. · Monitor item: Hydraulic oil temperature · Possible to display by service menu and moni- toring in monitor unit Monitor key switch. Check if displayed “ky” is highlighted in re- sponse to key switch operation.

YES Check if fault code 11901-3 or 11901-4 is displayed. 0 ° C or lower when starting · Monitor item: Key switch To A NO Faulty hyd. oil tempera- ture sensor, or open cir- cuit in harness between hyd. oil temperature sensor and MC. YES NO Faulty MC. Check if fault code 11004-2 is dis- played at the same time. A Refer to fault code 11004 in Troubleshooting A. YES T5-7-64