TROUBLESHOOTING / Troubleshooting B E-9 Faulty auto-idle system Even if control lever is turned to neutral, auto-idle system is not operated. Related MC Fault Code: 11004-2, 11304-3, 11304-4, 11307-3, 11307-4 Related ECM Fault Code: 639-2, 639-3 In case trouble symptoms E1 to E8 are recog- nized, perform the troubleshooting of these trou- bles first. Even if failure in pressure sensors (travel and front attachment) may have relevance to malfunc- tion of the auto-idle control. However, if these sensors fail, other operating functions will also be affected.
Connector (Harness end of connector viewed from the open side) Refer to the pages for Auto-Idle Control in the SYSTEM / Control System group in the T/M (Op- erational Principle). Check the wiring connections first. Connector Monitor-B T5-7-72 Check if fault code YES 11004-2 is dis- played. Check if fault code YES for MC or ECM is displayed. Monitor auto-idle switch. Faulty MC. YES Check if ON/OFF is NO shifted when auto-idle switch is Check if auto-idle is shifted. Open circuit in har- ness between displayed on monitor auto-idle switch and unit. NO MC. · Auto-idle switch: ON Disconnect connec- tor monitor-B in YES Faulty auto-idle monitor unit. switch.