TROUBLESHOOTING / Troubleshooting B A-4 Right travel is operated during single travel operation. Single bucket operation speed becomes slow. Boom is not raised properly during arm level crowding. (All problems occur at the same time.) Related MC Fault Code: None The pump 1 flow rate is minimized (approx. 20 L/min) due to some reasons. Accordingly, the right travel motor and bucket cylinder, which are actuated by pressure oil from pump 1, moves very slow. Pressure oil from pump 2 is also routed to the arm and boom cylinders so that the arm and boom can move at a slightly slow speed in single operation.
However, in level crowd operation, pressure oil is routed to the arm prior to the boom so that boom is scarcely raised. Refer to the SYSTEM / Hydraulic System group in the T/M (Operational Principle). YES Faulty pump 1 regulator. Monitor pump 1 pump control pressure. Check if pressure in- creases in proportion to right travel lever stroke. · Monitor item: Pump 1 pump control pressure · Possible to display by service menu and moni- toring in monitor unit. Bound pump 1 flow rate con- trol valve in signal control valve. NO T5-7-93