hitachi — FRONT ATTACHMENT SYSTEM TROUBLESHOOTING

TROUBLESHOOTING / Troubleshooting B F-9 When boom raise or arm roll-out is operated, boom or arm starts to move after moving slightly downward. Related MC Fault Code: None YES Faulty anti-drift valve. YES Check if anti-drift valves (arm and boom) are bound or scored. NO Oil leaks in cylinder. Check if load check valve in control valve is normal. · Disassemble / Visual Inspection NO Faulty load check valve. NOTE: 1. During the initial stage of operation, oil pressure and flow rate from the pump is low.

Therefore, if the load check valve is malfunctioning, the oil in the bottom side of the boom cylinder flows back into the circuit through the load check valve so that the boom cylinder temporarily is re- tracted. (B) When the Load Check Valve is Faulty: (A) 2. As oil pressure and flow rate from the pump is low, if oil leaks from bottom side (A) to rod side (B) due to faulty boom cylinder piston or cylinder barrel, the boom cylinder is temporarily re- tracted during the initial stage of opera- tion. In addition, cylinder force is re- duced. The cylinder drift increases in this case. T105-07-04-012 T5-7-109