TROUBLESHOOTING / Troubleshooting B F-11 Boom lower above ground is faster than other actuators during combined operation. Related MC Fault Code: None Boom lower meter-in cut valve or boom flow rate control valve may be faulty. Refer to the pages for the SYSTEM / Hydraulic System group and the COMPONENT OPERA- TION / Control Valve group in the T/M (Opera- tional Principle). In case boom lower single operation is slow, refer to F-8. YES Faulty boom lower meter-in cut valve. Check if boom lower meter-in cut valve is bound or scored. YES Faulty boom flow rate control valve. Check if boom flow rate control valve is bound or scored. Find out cause of trouble by tracing other trouble symptoms.
NO NO T1V1-05-04-005 T1V1-03-03-026 T5-7-112 Boom Cut Va Boom Cut Va Lower Meter-In lve Boom Flow Rate Control Valve