hitachi — FRONT ATTACHMENT SYSTEM TROUBLESHOOTING

TROUBLESHOOTING / Troubleshooting B Faulty auxiliary flow rate control solenoid valve. YES YES Check if auxiliary flow rate control solenoid valve is bound or scored. Check if auxiliary flow rate control valve in control valve is bound or scored. Faulty MC. YES Faulty auxiliary flow rate control valve in control valve. Check for continuity in harness between MC and auxiliary flow rate control solenoid valve.

YES NO · Between terminal #A23 of connector MC-A in MC and ter- minal #1 of connector in auxiliary flow rate control solenoid valve · Between terminal #A7 of connector MC-A in MC and terminal #2 of connector in auxiliary flow rate control sole- noid valve NO A Open circuit in harness between MC and auxiliary flow rate control solenoid valve. NO Shorted circuit in harness between MC and pres- sure sensor (arm roll-out). NO T5-7-115 Disconnect connec- Check if voltage be- tor MC-D in MC. YES tween terminals #D9 Check for continuity of harness end of To A between terminal connector MC-D and Disconnect connec- YES #D9 of harness end machine is 0 V.

tor in pressure sen- of connector and · Key switch: ON sor (arm roll-out). terminal #2 of har- NO Check if voltage be- ness end of connec- Open circuit in harness Switch pressure tween terminals #1 tor in pressure sen- between MC and pressure sensor (arm roll-out) and #3 of harness sor (arm roll-out). NO sensor (arm roll-out). with other pressure end of connector is YES sensor. 5±0.5 V. Check if fault code for switched pres- · Key switch: ON Open circuit in harness sure sensor is dis- Check if voltage be- YES between MC and pressure played. tween terminals #1 of sensor (arm roll-out) (ter- harness end of con- minal #3).

nector in pressure NO sensor (arm roll-out) and machine is be- Open circuit in harness tween 0.25 and 4.75 between MC and pressure V. NO sensor (arm roll-out) (ter- · Key switch: ON minal #1). Faulty pressure sensor (arm roll-out). YES Shorted circuit in harness between MC and pressure NO sensor (auxiliary). Check if voltage be- YES tween terminals #D9 of harness end of To A connector MC-D and machine is 0 V. Shorted circuit in harness between MC and pressure sensor (auxiliary).