hitachi — FRONT ATTACHMENT SYSTEM TROUBLESHOOTING

TROUBLESHOOTING / Troubleshooting B NO Shorted circuit in harness between MC and pres- sure sensor (arm roll-out). Disconnect connector MC-D in MC. Check if voltage between ter- minals #D9 of harness end of connector and machine is 0 V. Disconnect connector MC-B in MC and con- nector in auxiliary flow combining solenoid valve. Check for continuity between terminals #1 and #2 of harness end of connector in auxil- iary flow combining solenoid valve. NO Disconnect connector in pressure sensor (arm roll-out). Check if voltage be- tween terminals #1 and #3 of harness end of connector is 5 ± 0.5 V. YES Check if auxiliary flow combining solenoid valve is bound or scored.

To A YES Shorted circuit in harness between MC and auxil- iary flow combining so- lenoid valve. YES · Key switch: ON YES Open circuit in harness between MC and pres- sure sensor (arm roll-out) (terminal #3). Check if voltage be- tween terminals #1 of harness end of con- nector in pressure sensor (arm roll-out) and machine is be- tween 0.25 and 4.75 V NO Open circuit in harness between MC and pres- sure sensor (arm roll-out) (terminal #1). NO · Key switch: ON Faulty pressure sensor (arm roll-out). YES Faulty auxiliary flow combining solenoid valve. YES A YES Faulty auxiliary flow combining valve. Faulty MC.

NO T5-7-117 NO C Check if auxiliary flow combining valve in NO control valve is bound or scored.