TROUBLESHOOTING / Troubleshooting B SWING SYSTEM TROUBLESHOOTING S-1 Swing is slow or unmoving. Related MC Fault Code: None Check whether the pilot system is faulty or the main circuit is faulty. In case other functions (front attachment and travel) operate normally, the pilot pump is consid- ered to be normal. If the pilot system is displaying a problem, the cause of trouble may exist in the circuit after pilot valve. In case left travel speed is also slow, refer to A-3. · Specification: Refer to Operational Performance Test Sec- tion. · Monitor item: Swing control pressure · Possible to display by service menu and monitoring in monitor unit. Monitor secondary pilot pressure.
Check if secondary pilot pressure is nor- mal. T5-7-120 Check if swing motor YES parking brake release valve is scored or bound. Check if parking brake release pressure is YES approx. 3.9 MPa (40 kgf/cm2). · Relieve arm circuit. Faulty swing parking · Monitor item: brake release spool in Monitor pump control NO Front attachment con- signal control valve. pressure. trol pressure YES While slowly operating · Possible to display by swing lever, check if service menu and pump control pressure monitoring in monitor varies smoothly. unit. · Monitor item: Pump 2 pump control pressure Bound pump 2 flow rate · Possible to display by control valve in signal service menu and control valve.
monitoring in monitor NO unit. Faulty pilot valve. NO YES Faulty pilot valve. NO