TROUBLESHOOTING / Troubleshooting B STEP 2 Present Trouble Diagnosing The LCD indicates the fault codes for present ab- normalities of the mix door, mode encoder, and/or sensors. In case any abnormalities are present, the LCD in- dicates the fault codes. If more than one fault code is detected, the following fault code is displayed af- ter flashing (0.5 seconds) twice. Fan Switch LCD T178-05-08-001 OFF Switch : When solar radiation is shaded, the solar radiation sensor indicates the fault code of open circuit. Select the next step in order to be performed by op- erating the switches as follows: Push the upper side of fan switch: To proceed to “STEP 3.” Push the lower side of fan switch:
To return to “STEP 1.” Keep pushing the OFF switch for more than 3 seconds: Deactivate the self-diagnostic system. (Normal function is resumed) T5-7-136 Fault Code Open Circuit Shorted Circuit Mix Door 21 −21 Mode Encoder 22 In-Cab Ambient Temperature Sensor 23 −23 Outdoor Ambient Temperature Sensor 24 −24 Coolant Tem- perature Sensor 25 −25 Solar Radiation Sensor ∗ 26 −26