TROUBLESHOOTING / Troubleshooting B STEP 4 Sensing Temperature Display The LCD indicates the sensing temperature detected by each temperature sensor (excluding the insulation sensor). The sensing temperature detected by the in-cab ambient temperature sensor, outdoor ambient tem- perature sensor and coolant temperature sensor are displayed on the LCD in real time. (Figures less than the decimal point are not displayed.) Fan Switch Air Conditioner Switch Fan Mark LCD T178-05-08-001 NOTE: The coolant temperature sensor indicates “H” when coolant temperature is more than 21 ° C (70 ° F) and “L” when coolant tem- perature is less than 21 ° C (70 ° F).
Sensing temperature detected by each sensor is automatically displayed on the LCD and is cycled at an interval of 3 seconds with the timer. The timer is turned ON or OFF by operating the fresh air vent switch. Referring to the fan mark can check which sensing temperature is displayed. Select the next step in order to be performed by op- erating the switches as follows: Push the upper side of fan switch: To proceed to “STEP 5.” Push the lower side of fan switch: To return to “STEP 3.” Keep pushing the OFF switch for more than 3 seconds: Deactivate the self-diagnostic system. (Normal function is resumed.) Fresh Air Vent Switch OFF Switch T5-7-138