Cooling System/Water Pump (standard model) WATER PUMP IMPELLER INSTALLATION Place water pump under a press so that the thrust when pressing on impeller is received only by the pump shaft face. Using special tool JD-262A or JDE74, press impeller onto pump shaft until flush with pump housing face within a given tolerance of +0 mm (0 in.) and -0.25 mm (0.01 in.). CD30292 -UN-06MAR95 CD30293 -UN-17FEB95 CD,3274,G30,10 -19-07APR92 CTM3274 (01JUL99) 30-15 Saran Liter Engines 060799 PN=214 INSTALL PULLEY OR HUB -UN-04MAY98 -UN-16JUN98 CD30638 CD30652 1. Place pump housing under a press and support on 2. Install pulley or hub to the specified dimension “A” impeller end of shaft.
(see specifications). CD,3274,G30,47 -19-04JAN99 30 15