John Deere 3029, 4039, 4045, 6059, 6068 — TEST SHUT-OFF SOLENOID ON LUCAS-CAV INJECTION PUMP

Fuel System - Operation and Tests/Distributor Injection Pump CTM3274 (01JUL99) 220-8 Saran Liter Engines 060799 PN=347 TEST SHUT-OFF SOLENOID ON LUCAS-CAV INJECTION PUMP 1. With the pump installed on engine, check for an audible “click” when the ignition is switched on. 2. If a “click” cannot be heard, check for operating voltage from the terminal. 3. If no voltage, check corresponding electrical circuit (fuse, switch, wire...). 4. If voltage is correct, remove the solenoid carefully, ensuring that the plunger (4) and spring (3) do not fall out. Cover the exposed threaded bore in the pump to prevent dirt ingress. -UN-22FEB99 5. Check that the plunger moves freely in the solenoid body.

CD30739 6. Check the condition of the spring and the rubber valve seat. 7. Connect the assembled solenoid to ground and apply the appropriate voltage (12 V or 24 V) in order to check 1—Solenoid body if the solenoid operates correctly. Replace solenoid if test 2—O-ring seal is not satisfactory. 3—Spring 4—Plunger 8. Refit the solenoid assembly in the hydraulic head and tighten to 15 N·m (11 lb-ft). 9. Reconnect the electrical supply and check for satisfactory operation. CD,3274,G220,17-19-04JAN99 220 8