11 Fieldwork 11.8 Cleaning unit 67087 Adjust the cleaning performance monitor sensors. Set the sensitivity of the cleaning display and the desired individual grain loss limit at switch (6). 5 The display reacts more sensitive / less sensitive, depending on the adjusted set value. Check the grain loss limit. Proceed as follows: Prepare fieldwork. Set the machine depending on the crop. See threshing chart. Engage front attachment. Engage the threshing mechanism. Drive the machine into the crop at the speed appropriate for the crop. Stop the machine when the forth to fifth light of the meter light (5) lights up constantly after a sufficient distance has been covered.
Check the losses in the swath. If loss is at an acceptable level, continue operation with selected setting. When losses on the sieve are too high, increase the gauge sensitivity by about half to one step, using switch (6). Now adjust forward speed until the fourth or fifth light in the meter light (5) lights up again. When excessive losses on the sieve continue, check the machine setting regarding concave clearance, drum speed, fan speed and sieve setting. 6 DOMINATOR 150 / 140 19558 50 6 5 51 DOMINATOR 130 19412 When the cleaning is properly adjusted, one of the lights at the bottom of the meter light (5) lights up.
The cleaning and separation performance monitor should be adjusted as described to suit changing losses in the morning, when the crop is wet with dew, at noon when the crop is absolutely dry, and in the evening when the crop gradually gets damp. 222 00 0293 210 2 - BA DOMINATOR 150/140/130 - 12/09