33. HANDLING AUTO-GREASING SYSTEM With this system, the electric pump is connected to the divider valve, and a lubricating controller with built-in micro computer controls the electric pump and automatically supplies the grease. 33.1 METHOD OF OPERATING AUTO-GREASING SYSTEM 1. Turn the starting switch ON and start the electric pump. REMARK Immediately after the power is turned on, all display lamps on the lubrication controller inside the console box will light up for several seconds. This is a self-check for the lamps, and does not indicate any abnormality.
The display portion for starting the calculation of the greasing interval will flash, but all other displays will go out after a few seconds. However, even if the greasing interval has not been reached, if the switch is turned ON/OFF repeatedly, greasing will automatically start due to the function of the supplemental circuit, immediately after the starting switch is turned ON. After display of the 7-segment LED and greasing-in-progress LED, as shown in the LUBRICATION CONTROLLER DISPLAY TABLE, the above condition will be re- turned. 2. When the starting switch is turned ON, centralized greasing is carried out in accordance with the set time and frequency limit for greasing. 5-32