13303.02 Abnormal Thermister Temperature MS12501,000003D –19–26MAY06–1/1 Monitor Temperature Diagnostics Temperature in or around monitor controller is above 85 ° C (185 ° F). –1/1 TM2361 (24JUN08) 9001-50-1 450DLC Excavator Operation and Tests 062608 PN=201 Group 50 Monitor Controller (MON) Diagnostic Trouble Codes Monitor Controller (MON) Diagnostic Trouble Codes The monitor controller (MON) diagnostic trouble codes may be viewed on the monitor, by using Dr. ZX, or by using SERVICE ADVISOR. See the following procedures for viewing the information controller diagnostic trouble codes. • See Reading Diagnostic Trouble Codes With Monitor Display.
(Group 9015-20.) • See Reading Diagnostic Trouble Codes With Service ADVISOR Diagnostic Application. (Group 9015-20.) • See Reading Diagnostic Trouble Codes With Dr. ZX. (Group 9015-20.) SERVICE ADVISOR is a trademark of Deere & Company LD30992,00004BE –19–23MAR06–1/1 9001 50 1 1 Temperature Check Check temperature around monitor controller. Is temperature high? YES: Go to Screen Check. NO: Monitor controller malfunction. Replace controller. See Monitor Controller Remove and Install. (Group 9015-20.) – – –1/1