TM2361 (24JUN08) 9005-10-4 450DLC Excavator Operation and Tests 062608 PN=220 Operational Checkout Procedure Monitor Start Up Check YES: Go to next check. NO: Check controller key signal switch 5A fuse (F18) (Marked POW ON). See Fuse and Relay Specifications. (Group 9015-10.) System Starting... 1 2 3 4 5 6 7 8 9 0 9005 F1 F2 F3 F4 10 4 TX1005660 –UN–06APR06 1 TX1005657 –UN–03APR06 1—Alternator Alarm Indicator Turn key switch to ON position. LOOK: Does monitor display system starting screen? LOOK: Does default screen with hour meter appear after system starting screen disappears? LOOK: Does alternator alarm indicator (1) appear on default screen?
– – –1/1 Operational Checkout Procedure Monitor Start Up Check System Starting... 1 2 3 4 5 6 7 8 9 0 F1 F2 F3 F4 TX1005660 –UN–06APR06 1 TX1005657 –UN–03APR06 1—Alternator Alarm Indicator Turn key switch to ON position. LOOK: Does monitor display system starting screen? LOOK: Does default screen with hour meter appear after system starting screen disappears? LOOK: Does alternator alarm indicator (1) appear on default screen? YES: Go to next check. NO: Check controller key signal switch 5A fuse (F18) (Marked POW ON). See Fuse and Relay Specifications. (Group 9015-10.) – – –1/1 10 4