Group 10 Main Controller (MCF) Diagnostic Trouble Codes 11000.02 Abnormal EEPROM MS12501,0000046 –19–14JAN06–1/1 Controller Hardware Diagnostics –1/1 TM2361 (24JUN08) 9001-10-1 450DLC Excavator Operation and Tests 062608 PN=25 Main Controller (MCF) Diagnostic Trouble Codes The main controller (MCF) diagnostic trouble codes may be viewed on the monitor, by using Dr. ZX, or by using SERVICE ADVISOR. See the following procedures for viewing the main controller diagnostic trouble codes. • See Reading Diagnostic Trouble Codes With Monitor Display. (Group 9015-20.) • See Reading Diagnostic Trouble Codes With Service ADVISOR Diagnostic Application.
(Group 9015-20.) • See Reading Diagnostic Trouble Codes With Dr. ZX. (Group 9015-20.) SERVICE ADVISOR is a trademark of Deere & Company LD30992,00001CC –19–10DEC05–1/1 9001 10 1 1 Code Check Clear and re-check diagnostic trouble codes. Is DTC 11000.02-Abnormal EEPROM still present? YES: Code is still present and machine does not operate. Replace main controller (MCF). See Main Controller (MCF) Remove and Install. (Group 9015-20). YES: Code is still present but machine is still operable. Go to Machine Function Check. NO: Main controller (MCF) is OK. – – –1/1