John Deere 450DLC — Controller Area Network (CAN) Theory of Operation

Sub-System Diagnostics This machine utilizes a Controller Area Network (CAN) on which devices communicate. The Engine Control Unit (ECU), Monitor Controller, Information Controller (ICF), and Main Controller (MCF) are all connected to the CAN. Operations and functions of these individual devices are covered separately. The devices on the CAN are connected via three twisted wires called a twisted triple. The twisted triple consists of a differential pair (high and low) and a shield wire. This method reduces interference and helps the devices communicate with minimal errors. There are two CAN termination resistors used in the CAN circuit.

The CAN termination resistors are 120 ohm resistors that are connected on opposite ends of the bus to avoid signal errors. Both termination resistors are contained in electrical components. See Engine Control Module (ECM) Circuit Theory of Operation. (Group 9015-15.) See Monitor Controller Circuit Theory of Operation. (Group 9015-15.) See Information Controller (ICF) Theory of Operation. (Group 9015-15.) See Main Controller (MCF) Circuit Theory of Operation. (Group 9015-15.) LD30992,000020C –19–15FEB06–2/2 9015 15 2 TM2361 (24JUN08) 9015-15-2 450DLC Excavator Operation and Tests 062608 PN=446