TM2361 (24JUN08) 9015-15-41 450DLC Excavator Operation and Tests 062608 PN=485 Sub-System Diagnostics The pilot shutoff circuit enables or disables (unlocks or contacts of both pilot shutoff switches. When ground is locks) the pilot oil, thus enabling or disabling the present at terminal B19, the monitor controller knows machine hydraulics. The pilot shutoff circuit consists of that the pilot shutoff circuit is functioning properly. If the following components:
ground is not present at terminal B19, the pilot control shutoff lever alarm indicator will appear on the monitor • Pilot shutoff switches 1 and 2 (S3 and S4) display, alerting the operator that the pilot shutoff • Pilot shutoff diode (V8) circuit is malfunctioning. For information on monitor • Pilot shutoff solenoid (Y10 alarms, see Alarm Occurrence Screen. (Operator’s • Pilot shutoff solenoid relay (K2) Manual.) • Security relay (K5) • Monitor controller (A4) NOTE: The monitor controller must detect a ground at • Security diode (V4) terminal B19 at all times, regardless of position • Engine stop switch (S14) of pilot shutoff lever.
• Starter relay (K4) • Starter protection relay (K18) —No ground is present at terminal B12 of the monitor • Starter relay diode (V5) controller. Terminals B2 and B12 are connected inside the monitor controller, so with no ground available at When the key switch is turned to the ON or START terminal B12, no ground is available to the coil of pilot position, power is available to the following shutoff solenoid relay (K2). Relay is de-energized. With components: the pilot shutoff solenoid relay de-energized, no ground is available to pilot shutoff solenoid (Y10). Solenoid is • Coil of pilot shutoff solenoid relay (K2) [from battery de-energized; pilot hydraulics are disabled.
relay (K19)] • Pilot shutoff solenoid (Y10) [from battery relay (K19)] —No ground is present at terminal C31 of main • Coil of security relay (K5) (from key switch terminal controller (MCF) (A3). With no ground available at M) terminal C31, the MCF knows the pilot shutoff is disabled. This input is used by the optional fan Pilot Shutoff Disabled (Locked)—For the pilot shutoff reversing circuit. For more information, see Main to be disabled, the pilot shutoff lever must be in the Controller (MCF) Theory of Operation. (Group rearward (LOCK) position.
When the pilot shutoff lever 9015-15.) is at this position, the cam levers of both pilot shutoff switches (S3 and S4) are in the down (released) Pilot Shutoff Enabled (Unlocked)—For the pilot position and continuity exists across the normally shutoff to be enabled, the pilot shutoff lever must be in closed contacts connecting the red and black wires of the forward (UNLOCK) position. When the pilot shutoff the pilot shutoff switches.
lever is at this position, the cam levers of both pilot shutoff switches (S3 and S4) are pushed up and When continuity exists across the normally closed continuity exists across the normally open contacts contacts of the pilot shutoff switches, the following (now closed), connecting the white and black wires of occur: the pilot shutoff switches. —Terminal B19 of monitor controller (A4) is connected When continuity exists across the normally open to cab harness ground 4 (W38), through pilot shutoff contacts of the pilot shutoff switches, the following diode (V8) (terminals 2 and 3) and the normally closed occur: Continued on next page LD30992,0000216 –19–27APR06–2/3 9015 15 41