John Deere 450DLC — Main Controller (MCF) Diagnostics Using Dr. ZX

TM2361 (24JUN08) 9015-20-48 450DLC Excavator Operation and Tests 062608 PN=538 References ATT4 P2 Max Swash Angle Adjustment Adjustment of lower limit of maximum pump 2 flow rate when using attachment L/min 0.5 L/min 100—367 L/min 367 L/min ATT4 Engine Speed Increase/Decrease Adjustment of engine speed when using attachment min-1 10 min-1 -500—100 min-1 0 min-1 ATT4 Secondary Pilot Relief Pressure Selection Secondary pilot relief valve ON/OFF selection ON, OFF — ON/OFF Unregistered ATT4 Selector Valve Selection Selector valve ON/OFF selection ON, OFF — C/V or 0/T Unregistered ATT4 Accumulator Selection Accumulator ON/OFF selection ON, OFF — ON/OFF Unregistered ATT4 2-Speed Selection 2-Speed selection ON/OFF selection ON, OFF — ON/OFF Off ATT5 ATT5 ATT Type Attachment selection BR, PU, CR, VI, Un, Non — BR, PU, CR, VI, Un, Non Unregistered ATT5 ATT No.

Attachment setting number selection 1, 2, 3, 4, 5 — 1 to 5 Unregistered ATT5 P1 Max Swash Adjustment of lower L/min 0.5 L/min 100—367 L/min 367 L/min Angle Adjustment limit of maximum pump 1 flow rate when using attachment ATT5 P2 Max Swash Adjustment of lower L/min 0.5 L/min 100—367 L/min 367 L/min Angle Adjustment limit of maximum pump 2 flow rate when using attachment ATT5 Engine Speed Adjustment of engine min-1 10 min-1 -500—100 min-1 0 min-1 Increase/Decrease speed when using attachment ATT5 Secondary Secondary pilot relief ON, OFF — ON/OFF Unregistered Pilot Relief Pressure valve ON/OFF Selection selection ATT5 Selector Valve Selector valve ON, OFF — C/V or 0/T Unregistered Selection ON/OFF selection ATT5 Accumulator Accumulator ON/OFF ON, OFF — ON/OFF Unregistered Selection selection ATT5 2-Speed 2-Speed selection ON, OFF — ON/OFF Off Selection ON/OFF selection Continued on next page LD30992,0000220 –19–25APR06–27/30 9015 20 48 ATT5 P1 Max Swash Angle Adjustment Adjustment of lower limit of maximum pump 1 flow rate when using attachment L/min 0.5 L/min 100—367 L/min 367 L/min ATT5 P2 Max Swash Angle Adjustment Adjustment of lower limit of maximum pump 2 flow rate when using attachment L/min 0.5 L/min 100—367 L/min 367 L/min ATT5 Engine Speed Increase/Decrease Adjustment of engine speed when using attachment min-1 10 min-1 -500—100 min-1 0 min-1 ATT5 Secondary Pilot Relief Pressure Selection Secondary pilot relief valve ON/OFF selection ON, OFF — ON/OFF Unregistered ATT5 Selector Valve Selection Selector valve ON/OFF selection ON, OFF — C/V or 0/T Unregistered ATT5 Accumulator Selection Accumulator ON/OFF selection ON, OFF — ON/OFF Unregistered ATT5 2-Speed Selection 2-Speed selection ON/OFF selection ON, OFF — ON/OFF Off