TM2361 (24JUN08) 9015-20-64 450DLC Excavator Operation and Tests 062608 PN=554 References 3. Turn learning switch to ON position (the position away from “E”). Learning switch is located under the fuse cover. 4. Monitor the pump learning procedure status with Dr. ZX. • Pump Regulator Learning SW: Displays status of learning switch • Pump 1 Regulator Learning Condition: Displays regulator learning condition after pump learning procedure has been performed. • Pump 2 Regulator Learning Condition: Displays regulator learning condition after pump learning –UN–27APR06 procedure has been performed. E • Pump 1&2 Regulator Learning Status:
– 1ln, 2ln—Display when a new main controller is installed and learning procedure has not been TX1007073 performed. – 1Su, 2Su—Display when pump learning procedure is successful. Learning Switch 9015 20 64 – 1Fa, 2Fa—Display when pump learning procedure 1—Learning Switch has failed. – 1Le, 2Le—Display when pump learning procedure is in progress. Continued on next page LD30992,00004C8 –19–08JUN06–2/4