John Deere 450DLC — Relay Test

TM2361 (24JUN08) 9015-20-94 450DLC Excavator Operation and Tests 062608 PN=584 References Relay Test For location of relays see Cab Harness (W1) Component Location. (Group 9015-10.) Connect a multimeter to terminals 1 and 2. –UN–27APR01 About 420—460 ohms must be measured. If not, relay has failed. T141788 Connect multimeter to terminals 3 and 4. Less than 0.4 ohms must be measured. If not, relay has failed. Connect multimeter to terminals 3 and 5, then 4 and 5. Multimeter must read open in both connections. If not, relay has failed. CAUTION: Do not connect relay directly to battery. Use a fused power source such as auxiliary power connector (X25) in cab or external power supply.

Connect 24 volts (+) to terminal 1, ground (-) terminal 2. Connect multimeter to terminals 3 and 5. Multimeter must read less than 0.4 ohms. If not, relay has failed. LD30992,0000229 –19–14MAR06–1/1 9015 20 94