Theory of Operation A1—Main Controller (MCF) Y12—Pump 1 Control Solenoid 15—Pump 1 27—Pilot Pump B36—Pump 1 Control Y13—Pump 2 Control Solenoid 16—Pump 2 28—Fan Drive Pump Pressure Sensor Y14—Fan Pump Control 17—Pump 1 Regulator 29—Fan Drive Pump Regulator B38—Pump 2 Control Solenoid 18—Pump 2 Regulator 180—Supply Oil Pressure Sensor Main Pump Delivery Flow Rate Control Pressure oil from the pilot pump (27) flows to the pump control solenoid valves (Y12 and Y13) in pump 1 and 2 regulator (17 and 18). The pilot sensors (B36 and B38) in the controlled circuit sends a signal to MCF (A3).

The MCF will send the signals to each pump control solenoid valve (Y12 and Y13) which controls the pump flow rate within each valve. Fan Pump Delivery Flow Rate Control Pressure oil from the pilot pump (27) flows to the fan pump control solenoid valve (Y14) in the fan pump regulator (29), MCF (A3) activates the fan pump control solenoid valve and controls delivery flow rate of the fan pump (28) in order to adjust temperatures in oil cooler, radiator and intercooler properly. LD30992,0000255 –19–25JUN08–4/4 9025 05 29 TM2361 (24JUN08) 9025-05-29 450DLC Excavator Operation and Tests 062608 PN=667