John Deere 450DLC — Pump 1 and 2 Regulator Operation

Theory of Operation 15—Pump 1 23—Check Valve 180—Supply Oil 202—Large Chamber 19—Servo Piston 24—Check Valve 182—Pilot Oil 203—Small Chamber 20—Load Sleeve 25—Pilot Piston 184—Return Oil Y12—Pump 1 Control Solenoid 21—Load Spool 27—Pilot Pump 200—Spring Valve 22—Feedback Link 83—To Right Control Valve 201—Pivot Pin Regulator Operation with Flow Rate Increasing— With pump 1 control solenoid (Y12) actuated, pilot oil controlled by the pump 1 control solenoid acts on the pilot piston (25), moving the load spool (21) to the right against the force of the spring (200). With the load spool in this position, the large chamber (202) of the servo piston (19) is open to the tank.

(22) to rotate clockwise, moving the load sleeve (20) to the right. The servo piston will continue to move to the left until the oil passages on the load sleeve and load spool are completely closed. With the servo piston in this position, the pump swash plate is moved toward maximum displacement; thus the pump flow rate will increase. The pump delivery flow rate will increase or decrease proportional to the pilot control pressure from the pump 1 control solenoid valve.

Supply oil moving into the small chamber (203) moves the servo piston to the left, causing the feedback link LD30992,0000258 –19–11APR06–4/4 9025 05 37 TM2361 (24JUN08) 9025-05-37 450DLC Excavator Operation and Tests 062608 PN=675