John Deere 450DLC — Travel Motor Speed Circuit Operation

TM2361 (24JUN08) 9025-05-108 450DLC Excavator Operation and Tests 062608 PN=746 Theory of Operation 5 3 4 1 2 6 1 7 2 –UN–25APR06 9 8 10 11 TX1006979 12 TX1006979 Travel Motor Fast Speed Operation 1—Swashplate Piston 4—Spool 6—Spool 9—Supply Oil 2—Swashplate 5—From Travel Speed 7—Counterbalance Valve 10—Pilot Oil 3—Travel Speed Selector Solenoid Valve (SB) 8—Cylinder Block 11—Return Oil Valve 9025 05 ,108 Travel Motor Fast Speed Operation—When fast routes pilot oil (10) to the travel speed selector valve speed travel (rabbit) mode is selected, the pump and (3).

Pilot oil pressure moves the spools (4 and 6) to valve controller sends a control signal to the power route supply oil to the swashplate pistons (1). The boost solenoid to increase system relief pressure swash plate pistons then move the swashplate (2) to setting and to travel speed solenoid valve (SB). minimum position. The reduced swashplate angle causes the motors to turn at a faster speed with When energized by the pump and valve controller reduced torque. control signal, the travel speed solenoid valve (SB) LD30992,000026A –19–25APR06–2/2