During Combined Functions, Boom Raise Speed Is Slow And Arm-In Is Jerky Diagnostic Procedure –1/1 TM2361 (24JUN08) 9025-15-20 450DLC Excavator Operation and Tests 062608 PN=770 Diagnostic Information 1 DTC Check See Reading Diagnostic Trouble Codes With Monitor Display. (Group 9015-20.) See Reading Diagnostic Trouble Codes With Service ADVISORDiagnostic Application Are any of the following DTC displayed? • 11303.03 See Arm Roll-in Pilot Pressure Continued Sensor Circuit Voltage High. . (Group 9001-10.) • 11303.04 See Arm Roll-in Pilot Pressure Continued Sensor Circuit Voltage Low. (Group 9001-10.) • 11402.03. See Boom Flow Rate Solenoid (SF) Valve Feedback Current High.
(Group 9001-10.) • 11402.04 See Boom Flow Rate Solenoid (SF) Valve Feedback Current Low. (Group 9001-10.) • 11995.03 See Arm Roll-Out Pilot Pressure Sensor Circuit Voltage High. (Group 9001-10.) • 11995.04 See Arm Roll-Out Pilot Pressure Sensor Circuit Voltage Low. (Group 9001-10.) • 11997.03 See Bucket Dump Pilot Pressure Sensor Circuit Voltage High. (Group 9001-10.) • 11997.04 See Bucket Dump Pilot Pressure Sensor Circuit Voltage Low. (Group 9001-10.) • 11998.03 See Boom Down Pilot Pressure Sensor Circuit Voltage High. (Group 9001-10.) • 11998.04 See Boom Down Pilot Pressure Sensor Circuit Voltage Low. (Group 9001-10.) • 11999.03 See Bucket Curl Pilot Pressure Sensor Circuit Voltage High.
(Group 9001-10.) • 11999.04 See Bucket Curl Pilot Pressure Sensor Circuit Voltage Low. (Group 9001-10.) YES: Diagnose and repair as required to clear displayed DTC. Diagnostic procedure complete. NO: Go to Boom Control Pressure Check. – – –1/1 2 Boom Control Pilot Pressure Check. Key on, use monitor service menu to display Swing / Front Attachment Control Pilot Pressure. See Monitor Service Menu Operation. (Group 9015-16.) Record control pilot pressure while doing a combined function of each problem circuit. Is maximum control pilot pressure approximately 3.9 MPA? YES: Repair pump flow rate pilot valve in signal manifold. See Pilot Signal Manifold Operation. (Group 9025-05.) NO:
Diagnose problem in main controller. See Main Controller (MCF) Diagnostics Using Dr. ZX. (Group 9015-20.). – – –1/1 9025 15 20