John Deere 450DLC — Auto Lubrication Does Not Operate Diagnostic Procedure

TM2361 (24JUN08) 9025-15-61 450DLC Excavator Operation and Tests 062608 PN=811 Diagnostic Information 4 Harness Check See System Functional Schematic, Wiring Diagram, and Component Location Master Legend. (Group 9015-10.) Remove harness connector from pressure sensor and main controller. Check for continuity between terminal #1 wire of harness. Is continuity measured? YES: Go to Pilot Valve Check. NO: Repair or replace harness. If harness ok diagnose main controller. See Main Controller (MCF) Diagnostics Using Dr. ZX. (Group 9015-20.) – – –1/1 5 Pilot Valve Check See Pilot Signal Manifold Operation. (Group 9025-05.) Inspect pilot valve. Is pilot valve in good working condition? YES:

Diagnostic procedure complete. NO: Adjust or replace pilot valve. Perform Pilot Pressure Regulating Valve Test and Adjustment. (Group 9025-25.) – – –1/1 Diagnose Auto Lubrication System Malfunctions MR50960,00000F9 –19–12APR06–1/1 9025 15 61 Auto Lubrication Does Not Operate Diagnostic Procedure NOTE: The maximum interval between auto lubrication is 90 minutes. The interval setting can be adjusted from 10 to 90 minutes. The lubricating cycle time takes 5 minutes. – – –1/1 1 Wiring Connector Check See System Functional Schematic, Wiring Diagram, and Component Location Master Legend. (Group 9015-10.) Are all the connectors in good condition? YES: Go to Auto Lubrication Mode Switch Check. NO:

Repair or replace connectors. – – –1/1 2 Auto Lubrication Mode Switch Check Turn auto lubrication mode on and check if display indicates auto. Is auto displayed? YES: Go to Lubrication Pump Status Check. NO: Go to Harness Check. – – –1/1