John Deere 450DLC — Auto Lubrication Alarm Is Displayed Diagnostic Procedure

Auto Lubrication Alarm Is Displayed Diagnostic Procedure NOTE: If auto lubrication alarm is displayed when auto lubrication stops, the problem may be no grease or proximity switch malfunction. –1/1 TM2361 (24JUN08) 9025-15-64 450DLC Excavator Operation and Tests 062608 PN=814 Diagnostic Information 1 Auto Lubrication Switch Check Turn auto lubrication switch to off. Does auto lubrication stop? YES: Replace auto lubrication relay K11. NO: Go to Harness Check. – – –1/1 2 Harness Check See System Functional Schematic, Wiring Diagram, and Component Location Master Legend. (Group 9015-10.) Disconnect harness connector B from main controller. Does auto lubrication stop? YES: Replace . NO:

Repair short in harness K11 and / or replace. – – –1/1 1 Auto Lubrication Grease Check Check for following problems: • No grease in cartridge. • Air mixed in grease circuit. • Plug sealing grease cartridge. Is grease supply in good condition? YES: Replace proximity switch. See System Functional Schematic, Wiring Diagram, and Component Location Master Legend. (Group 9015-10.) NO: Diagnostic procedure complete. – – –1/1 9025 15 64 2 Harness Check See System Functional Schematic, Wiring Diagram, and Component Location Master Legend. (Group 9015-10.) Disconnect harness connector B from main controller. Does auto lubrication stop? YES: Replace . NO:

Repair short in harness K11 and main controller. – – –1/1