TM2361 (24JUN08) 9025-25-14 450DLC Excavator Operation and Tests 062608 PN=874 Tests Power Dig Solenoid Valve (port SG) Test and Adjustment SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position OFF Power Dig Switch Position ON Power Dig Solenoid Valve (port Monitor Reading ± 0.2 MPa SG) Pressure Monitor Reading ± 200 kPa Monitor Reading ± 2.0 bar Monitor Reading ± 29.0 psi Actual Reading From Gauge Must Be Within Pressure Range of Monitor Reading and Tolerance.
Solenoid Valve Adjusting Screw 0.069 MPa approximate per 1/4 Pressure Change turn 69 kPa approximate per 1/4 turn 0.69 bar approximate per 1/4 turn 10 psi approximate per 1/4 turn End of Adjusting Screw-to-Nut 2 mm maximum Length 0.079 in. maximum Solenoid Valve Adjusting 3.0 N•m Screw-to-Housing Nut Torque 27 lb-in. SERVICE EQUIPMENT AND TOOLS JT03191 (7/16-20 M 37° x 7/16-20 F 37° x 7/16-20 M 37°) (Parker No.
063T-4-4) Tee 9025 25 14 JT02156A Digital Pressure/Temperature Analyzer JT02162 Transducer 35 000 kPa (350 bar) (5000 psi) Gauge 7 MPa (7000 kPa) (70 bar) (1000 psi) Purpose of test is to check that the output pressure from the power dig solenoid valve to the power digging valve is within the specified pressure range.
Continued on next page LD30992,00002B1 –19–05JUN06–1/5 SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position OFF Power Dig Switch Position ON Power Dig Solenoid Valve (port SG) Pressure Monitor Reading ± 0.2 MPa Monitor Reading ± 200 kPa Monitor Reading ± 2.0 bar Monitor Reading ± 29.0 psi Actual Reading From Gauge Must Be Within Pressure Range of Monitor Reading and Tolerance.
Solenoid Valve Adjusting Screw 0.069 MPa approximate per 1/4 Pressure Change turn 69 kPa approximate per 1/4 turn 0.69 bar approximate per 1/4 turn 10 psi approximate per 1/4 turn End of Adjusting Screw-to-Nut 2 mm maximum Length 0.079 in. maximum Solenoid Valve Adjusting 3.0 N•m Screw-to-Housing Nut Torque 27 lb-in. SERVICE EQUIPMENT AND TOOLS JT03191 (7/16-20 M 37° x 7/16-20 F 37° x 7/16-20 M 37°) (Parker No. 063T-4-4) Tee JT02156A Digital Pressure/Temperature Analyzer JT02162 Transducer 35 000 kPa (350 bar) (5000 psi) Gauge 7 MPa (7000 kPa) (70 bar) (1000 psi)