John Deere 450DLC — Travel Speed Solenoid Valve (port SI) Test and Adjustment

TM2361 (24JUN08) 9025-25-20 450DLC Excavator Operation and Tests 062608 PN=880 Tests NOTE: Pressure reading displayed on the monitor is a calculated pressure from an electrical signal in the main controller (MCF). The reading does not change when valve adjustment is made. The actual pressure to the travel speed selector valves must be measured using a gauge. Y23 1. Release pressure from hydraulic oil tank by pushing Y22 pressure release button on top of hydraulic oil tank. –UN–10FEB06 Y25 2. Disconnect line for travel speed solenoid valve (Y25) to travel speed selector valves (164) from elbow at the Y24 bottom of solenoid valve manifold (55). TX1003387 55 84 83 66 Install 203836 tee.

Solenoid Valve Manifold Location 3. Connect the JT02156A Digital Pressure/Temperature Analyzer and JT02162 Transducer or a 7 MPa (7000 kPa) (70 bar) (1000 psi) gauge. See JT02156A Digital Pressure/Temperature Analyzer Installation.

Y22—Boom Flow Rate Solenoid Valve (port SF) Y23—Boom Mode Solenoid Valve (port SC) Y24—Power Dig Solenoid Valve (port SG) –UN–13FEB06 Y25—Travel Speed Solenoid Valve (port SI) 55—Solenoid Valve Manifold 66—Pilot Signal Manifold 83—Right Control Valve (4-spool) TX1003386 84—Left Control Valve (5-spool) 85—To Main Relief and Power Digging Valve 97—To Boom Flow Rate Control Valve—Switch Valve 129—To Boom Mode Relief Control Valve Travel Speed Solenoid Valve (port SI) 164—To Travel Speed Selector Valve (left and right travel motors) 9025 25 20 Continued on next page LD30992,00002B2 –19–05JUN06–2/5