John Deere 450DLC — Boom Mode Solenoid Valve (port SC) Test and Adjustment

TM2361 (24JUN08) 9025-25-26 450DLC Excavator Operation and Tests 062608 PN=886 Tests NOTE: The calculated pressure reading for boom mode solenoid valve does not displayed on the monitor in cab. Use the SERVICE ADVISOR application or Dr. ZX application. 5. Warm hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure. (Group 9025-25.) Specification Hydraulic Oil—Temperature........................................................ 45—55°C 110—130°F 6. Run machine at specification. Specification Engine—Speed............................................................................ Fast Idle Work Mode Switch—Position......................................................

Dig Mode Power Mode Switch—Position.............................. HP (High Power) Mode Auto Idle Switch—Position.................................................................. OFF Boom Mode Switch—Position............................................................... ON 7. Slowly actuate boom down function. The machine will lift slightly and then stop as boom mode relief valve opens. Record pressure readings from monitor and gauge. 8. Calculate the pressure range using the calculated reading from monitor and the specify tolerance. Check that the actual reading from gauge is within the pressure range.

Specification 9025 25 26 Boom Mode Solenoid Valve (port SC)—Pressure................................................ Monitor Reading ± 0.2 MPa Monitor Reading ± 200 kPa Monitor Reading ± 2.0 bar Monitor Reading ± 29.0 psi Actual Reading From Gauge Must Be Within Pressure Range of Monitor Reading and Tolerance. Continued on next page LD30992,00002B0 –19–05JUN06–3/5