John Deere 450DLC — Main Relief and Power Digging Valve Test and Adjustment

TM2361 (24JUN08) 9025-25-32 450DLC Excavator Operation and Tests 062608 PN=892 Tests Main Relief and Power Digging Valve Test and Adjustment SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position Off Boom Mode Switch Position Off Main Relief Valve Pressure 30.4—32.9 MPa 30 400—32 900 kPa 304—329 bar 4410—4770 psi Power Digging Valve Pressure 32.8—35.3 MPa 32 800—35 300 kPa 328—353 bar 4770—5120 psi Second Adjusting Plug Pressure 4.5 MPa approximate per 1/4 turn Change 4500 kPa approximate per 1/4 turn 45 bar approximate per 1/4 turn 655 psi approximate per 1/4 turn 41 mm Nut Torque 98 N•m 70 lb-ft First Adjusting Plug Pressure 4.5 MPa approximate per 1/4 turn Change 4500 kPa approximate per 1/4 turn 45 bar approximate per 1/4 turn 655 psi approximate per 1/4 turn 30 mm Nut Torque 59 N•m 45 lb-ft 9025 25 32 SERVICE EQUIPMENT AND TOOLS JT02156A Digital Pressure/Temperature Analyzer JT02160 Transducer, 70 000 kPa (700 bar) (10,000 psi) 4200465 (1/4 M BSPP ORB x 7/16-20 M 37°) Adapter 70 000 kPa (700 bar) (10,000 psi) Gauge The purpose of main relief valve is to limit the maximum system pressure in the hydraulic system.

Power digging is a temporary increase of system pressure. The valve is checked and adjusted to protect components from damage caused by excessive pressures.

Continued on next page LD30992,0000280 –19–05JUN06–1/6 SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position Off Boom Mode Switch Position Off Main Relief Valve Pressure 30.4—32.9 MPa 30 400—32 900 kPa 304—329 bar 4410—4770 psi Power Digging Valve Pressure 32.8—35.3 MPa 32 800—35 300 kPa 328—353 bar 4770—5120 psi Second Adjusting Plug Pressure Change 4.5 MPa approximate per 1/4 turn 4500 kPa approximate per 1/4 turn 45 bar approximate per 1/4 turn 655 psi approximate per 1/4 turn 41 mm Nut Torque 98 N•m 70 lb-ft First Adjusting Plug Pressure 4.5 MPa approximate per 1/4 turn Change 4500 kPa approximate per 1/4 turn 45 bar approximate per 1/4 turn 655 psi approximate per 1/4 turn 30 mm Nut Torque 59 N•m 45 lb-ft