John Deere 450DLC — Fan Drive Pump Flow Test

TM2361 (24JUN08) 9025-25-85 450DLC Excavator Operation and Tests 062608 PN=945 Tests 6. Remove cover over the control valve for access to the fan drive system relief valve (38). Turn adjusting screw for relief valve out one full turn. NOTE: Relief valve is turned out to decrease system –UN–26APR06 pressure so pump flow can be checked at the lower pressure. 7. Use one of the following test equipment to display oil TX1006883 temperature and engine speed: 1. SERVICE ADVISOR application. See SERVICE Fan Drive System Relief Valve ADVISOR Connection Procedure for instruction. 38—Fan Drive System Relief Valve (Group 9015-20.) Access Fan Drive Pump Flow Test.

Or select the following items from the menu: • Hydraulic Oil Temperature • Actual Engine Speed 2. See Personal Digital Assistant (PDA) Connection To Excavator Using Dr. ZX Application for instruction. (Group 9015-20.) Select the following items from the Monitor Display: • Hydraulic Oil Temperature • Actual Engine Speed 3. See Monitor Service Menu Operation for instruction to actuate the service menu on monitor in cab. (Group 9015-20.) Select the following items from Monitoring list: • Hydraulic Oil Temperature • Actual Engine Speed 8. Disconnect the vacuum pump. 9. Check that flowmeter loading valve is open. 10. Heat hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure.

(Group 9025-25.) Specification Hydraulic Oil—Temperature........................................................ 45—55°C 110—130°F SERVICE ADVISOR is a trademark of Deere & Company Continued on next page OUT3035,000000D –19–05JUN06–4/6 9025 25 85