John Deere 450DLC — Fan Drive Pump Flow Test

TM2361 (24JUN08) 9025-25-87 450DLC Excavator Operation and Tests 062608 PN=947 Tests Specification Fan Drive Pump—Flow Rate— Minimum Allowable............................... 48.4 L/min at 23.3 MPa and 1750 rpm 48.4 L/min at 23 305 kPa and 1750 rpm 48.4 L/min at 233.1 bar and 1750 rpm 12.8 gpm at 3380 psi and 1750 rpm Fan Drive Pump—Flow Rate— Minimum Allowable............................... 42.8 L/min at 26.3 MPa and 1750 rpm 42.8 L/min at 26 270 kPa and 1750 rpm 42.8 L/min at 262.7 bar and 1750 rpm 11.3 gpm at 3810 psi and 1750 rpm 13. Open loading valve. Stop the engine. Pump flow rate can be increased some by adjusting the pump servo piston maximum flow adjusting screw.

See Fan Drive Pump Servo Piston Maximum Flow Test and Adjustment. (Group 9025-25.) 14. Turn adjusting screw for fan drive system relief valve back to its original setting. OUT3035,000000D –19–05JUN06–6/6 9025 25 87