TM2361 (24JUN08) 9031-15-3 450DLC Excavator Operation and Tests 062608 PN=955 Diagnostic Information Symptom Problem Solution Refrigerant hose kinked, pinched, or Re-route or re-index hoses. Replace collapsed collapsed hoses. See Heater and Air Conditioner Component Location. (Group 9031-15.) See Refrigerant Hoses and Tubing Inspection. (Group 9031-25.) Heater or evaporator fins restricted Clean heater or evaporator fins. See with dirt or dust Heater and Air Conditioner Component Location. (Group 9031-15.) See Heater and Air Conditioner Remove and Install. (Group 1830.) Air conditioner and heater mixer Check door for obstructions and test servomotor door open servomotor.
See Air Conditioner Harness (W6) Wiring Diagram. (Group 9015-10.) Compressor clutch slipping or failed Check compressor clutch. Perform Air Conditioner Compressor Clutch Test. (Group 9031-25.) Warm outside air leaking into cab Inspect, repair, or replace door and window seals. See Windowpanes Repair. (Group 1810.) and See Sliding Window Repair. (Group 1810.) System refrigerant (R134a) charge Perform R134a Air Conditioning low System Test. (Group 9031-25.) and Perform Refrigerant Leak Test. (Group 9031-25.) Evaporator fins frosting or freezing Freeze control switch not positioned correctly in evaporator core. Reposition switch in evaporator core.