Perkins — Perkins 1104E Engine Systems Operation Testing and Adjusting Manual

28 SENR9977 Systems Operation Section Power Supply for the Pressure Sensors g01143335 Illustration 36 Schematic for pressure sensors The ECM supplies 5.0 ± 0.2 DC volts through the ECM connector to each sensor. The power supply is protected against short circuits. A short in a sensor or a wiring harness will not cause damage to the ECM. Power Supply for the Throttle Position Sensor g01134572 Illustration 37 Schematic for the throttle position sensor The ECM supplies 8.0 ± 0.4 DC volts through the ECM connector to the sensor. The power supply is protected against short circuits. A short in a sensor or a wiring harness will not cause damage to the ECM.