Komatsu — METHOD OF OPERATING AUTO-GREASING SYSTEM

. ATTACHMENTS, OPTIONS HANDLING AUTO-GREASING SYSTEM (1) (2) (3) (4) (5) 7-segment LED Cancel key Level selector key Blade-type fuse Power source LED (6) (7) (8) (9) (10) Greasing LED Warning LED Setting LED Starting key Item selector key Remaining number of times of greasing If the remaining number of times of greasing is less than 10, remaining number is displayed and it flashes. If the remaining number of times is 10 or more, only the flashing is shown without displaying the number.

OPERATION AS DESIRED If auto-greasing switch (1) on the right switch panel or the start button of the lubrication controller inside the box under the step on the left side of the machine are pressed, one cycle of greasing will be carried out regardless of the hours of operation. The time count for the greasing interval will be canceled, and when the electric pump automatically stops, the count will start again. 6 - 32 LUBRICATION CONTROLLER DISPLAY TABLE