Komatsu — 3.2.14 BLOCK FUSE

DETAILED CONTROLS AND GAUGES 3.2.13 FUSE IMPORTANT Before replacing a fuse, be sure to turn off the starting switch. The fuses protect the electrical equipment and wiring from burning out. If the fuse becomes corroded, or white powder can be seen, or the fuse is loose in the fuse holder, replace the fuse. Replace the fuse with another of the same capacity. Fuse Capacities and Circuit Names 3.2.14 BLOCK FUSE If the starting motor does not turn even when the starting switch is turned to the ON position, block fuse (1) is probably blown, so open the cover at the right side of the machine and check or replace the fuse. This is at the top surface of the battery.

For details of the method of opening and closing the cover on the right side of the machine, see "3.2.10 COOLING COVER". NOTE A block fuse is a large fuse wire installed to the circuit where a large-capacity current is flowing. It acts in the same way as a normal fuse to protect the electrical equipment and wir- ing from burning out under abnormal current. 88 No.

Fuse capacity Name of circuit Canopy specification Cab specification (1) 30A Engine stop solenoid (2) 10A PPC solenoid, horn, fuel pump, safety relay (3) 10A Monitor panel, buzzer, speed boost solenoid (4) 10A If equipped (5) 10A 20A Heater, travel alarm buzzer (6) - 20A Room lamp, radio, windshield wiper, window washer (7) 10A Monitor panel, controller, radio (Cab specification) (8) 10A 20A Working lamp (9) - - (10) - - (11) 30A Spare (12) 10A 20A Spare (13) 10A Spare